Transfer Switches & Connection
Generator Interlock Kit for a 200 Amp Panel
Searching by amperage gets you half the specification. The half that decides whether the kit fits is the gap between your main breaker and the one next to it.
Written byMike M.
Published
Disclosure: we earn a commission on purchases made through links on this page, at no cost to you. It does not affect what we recommend or what we say about it — how we are funded.
The short answer
A 200 amp interlock kit is not a universal part. It is specified by your panel's brand and series first, then by the published spacing between the main breaker and the branch breaker the generator breaker will occupy — the kits in our registry state 3/16 inch drill bits, 7/8 to 1 1/4 inch spacing, and 1 1/4 to 1 7/16 inch spacing, all for different panels. Buy to the brand and the measurement, not to the amperage, and have it installed by an electrician: this is permanent wiring on the supply side of your panel.
Almost everyone searches for this the same way — the panel says 200 amps, so the kit should say 200 amps. That is a real part of the specification and it is the smaller part. An interlock is a piece of steel that slides over two breaker handles and makes it physically impossible for both to be on at once. Whether it fits depends on exactly where those two handles are.
The three things that decide fit
What you need to know before ordering
- 1. Panel brand and series
- Square D QO, Homeline, Eaton BR, Siemens, Murray
- 2. Panel amperage
- 100/125 A and 150/200 A take different kits
- 3. Breaker spacing
- Measured, in inches, between main and branch handles
- 4. Neutral type
- Plug-on-neutral changes the spacing on some panels
- Where to read them
- The label inside your panel door
Open the panel door and photograph the label. Every figure above except the spacing is printed on it, and the spacing is a tape measure. Do not remove the dead front cover to do this.
The fourth row catches people out. XMK publishes 7/8 inch spacing for plug-on-neutral Siemens and Murray panels and 1 1/4 inch for non-plug-on-neutral ones — same brand, same amperage, two different parts. If you buy on brand alone you have a coin-flip chance of the right one.
The published fit figures, kit by kit
| Panel | Kit | Published fit |
|---|---|---|
| Square D QO / Homeline, 150-200 A | SPZOCE | Manufacturer specifies the required main-to-branch spacing; includes a 3/16 in steel drill bit for the cover |
| Square D QO / Homeline, 100-125 A | XMK | Single-handle horizontal throw, 3/4 to 7/8 in spacing |
| Eaton / Cutler-Hammer BR, 150-200 A | EXCELFU | 1 1/4 to 1 7/16 in spacing; covers BR with plug-in neutral and CH variants |
| Eaton / Cutler-Hammer BR, 100-125 A | SPZOCE | Adjacent main and generator breakers |
| Eaton BR, 100-125 A, factory part | Eaton BRMIKBR | Manufacturer states it meets NEC Article 702 |
| Siemens / Murray, 150-200 A | XMK | 7/8 to 1 1/4 in spacing |
| Siemens / Murray, 100 A | XMK | 7/8 in plug-on-neutral, 1 1/4 in non-plug-on-neutral |
The panel compatibility guide walks the same ground by brand rather than by amperage, and the best interlock kits ranks them.
The short answer
The 150-200 A kits
| # | Product | Best for | Score | Price |
|---|---|---|---|---|
| 1 | ![]() SPZOCE Interlock Kit — Square D QO/Homeline 150/200A The cheapest correct way to connect a generator to the whole panel, provided your panel is a Square D QO or Homeline with the exact spacing stated — measure first. | Square D QO and Homeline, 150-200A | 9.2/10 | $30.99 |
| 2 | ![]() EXCELFU Interlock Kit — Eaton BR 150/200A The affordable option for an Eaton BR panel, with the spacing published so you can verify fit — but check whether your inspector wants the factory kit. | Eaton / Cutler-Hammer BR panels | 8.9/10 | $19.99 |
| 3 | ![]() XMK Interlock Kit — Siemens/Murray 150/200A The third-party plate for a 150 or 200 A Siemens or Murray panel — it publishes the spacing range, so you can measure and confirm fit before ordering. | Siemens and Murray panels | 9.0/10 | $19.99 |
| 4 | ![]() Eaton BRMIKBR Factory Interlock Kit 100-125A Pay the premium for this one: a factory interlock with a stated NEC Article 702 basis removes both the fit risk and the inspection risk. | Factory kit that satisfies inspectors | 9.4/10 | $98.21 |
#ad Amazon prices as of November 19, 2026; they may have changed since. Scores are our editorial judgment from published specifications, not test results — how we pick. How we are funded.
Why there is no such thing as a compact or low-amperage interlock
A recurring search is for a small or low-amp interlock switch — something compact enough for a modest panel or a small generator. No such product class exists, and it is worth saying why rather than leaving the search unanswered.
An interlock is specified by the panel, never by the generator. A 2,000 watt inverter and a 13,000 watt tri-fuel machine use the identical kit on the identical panel, because the part is a mechanical slide over two breaker handles — it carries no current at all. The generator's output decides the breaker you install and the inlet and cord you buy, which is the amp rating guide and the cord gauge guide. It never decides the interlock.
So the smaller panels do have their own kits — 100 A and 125 A versions are listed in the table above — but they are smaller because the panel is, not because the generator is.
What a 200 A panel does and does not let you do
A 200 A main is about the capacity of the service, not the capacity of your backup. The generator breaker you back-feed through is sized to the generator — a 30 A double-pole for an L14-30 machine, a 50 A for a 14-50 one — and that breaker is the ceiling on what the house can draw while the main is off.
The practical consequence is that an interlock on a 200 A panel gives you access to every circuit in the house, which is its advantage over a transfer switch and also its hazard. A transfer switch has a fixed set of circuits chosen at installation to total less than the generator can carry; an interlock has none, so load management is yours to do by hand at the panel door. Interlock kit versus transfer switch is the full comparison, and how many watts to run a house is the arithmetic you will be doing in front of the breakers.
One more thing worth confirming before you order: legality. Interlocks are accepted in most US jurisdictions and the Eaton factory kit publishes that it meets NEC Article 702, but adoption varies and some inspectors require the manufacturer's own part rather than a third-party one. Are interlock kits legal covers how that is decided where you live, and it is a question to settle before the kit arrives rather than after.
The rest of the chain

The standard 30A inlet
Reliance Controls PB30 30A Power Inlet Box

The default generator cord
PlugSaf 25 ft 30A L14-30 Cord, 10 AWG

50A inlet with wire-size guidance
SURAIELEC PIB50B01 50A Power Inlet Box
An interlock is one of three parts. You also need an inlet box in the wall and a cord to reach the generator at the published 20-foot distance — a 30 A inlet rated 7,500 W for most machines, or a 50 A inlet for a larger one.
If the label inside your panel door says 100 or 125 amps rather than 200, the kit you need is a different part with a narrower throw. Compact interlock kits for small panels ranks those.
Questions people actually ask
Do I need a special interlock kit for a 200 amp panel?
You need one specified for your panel's brand, series and amperage band — 150/200 A kits are different parts from 100/125 A ones. Amperage alone is not enough: the kit also has to match the published spacing between your main breaker and the branch breaker beside it, which on some panels differs by whether yours is plug-on-neutral.
How do I know which interlock kit fits my panel?
Open the panel door, photograph the label for the brand, series and amperage, and measure the gap between the main breaker handle and the branch handle next to it. Then match all of it against the kit's published compatibility — for example 1 1/4 to 1 7/16 inch for the EXCELFU Eaton BR 150/200 A kit. Do not remove the dead front cover.
Does the generator size change which interlock kit I need?
No. The interlock is a mechanical slide over two breaker handles and carries no current, so the same kit serves a 2,000 watt inverter and a 13,000 watt tri-fuel machine on the same panel. The generator decides the breaker, the inlet and the cord, never the interlock.
Is there a compact or 10 amp interlock switch?
No, and the search is based on a misunderstanding worth correcting: interlocks are not rated by current because they do not carry any. Smaller kits exist for smaller panels — 100 A and 125 A versions — but they are sized to the panel, not to a small generator.
Can I install a 200 amp interlock kit myself?
In most US jurisdictions, no. It is permanent work on the supply side of your panel and requires a permit and an inspection, and some inspectors require the panel manufacturer's own kit rather than a third-party one. Settle that question before you order.
Does an interlock let me run the whole house on 200 amps?
It gives you access to every circuit, which is not the same thing. The ceiling is the generator breaker you back-feed through — typically 30 A or 50 A — and because an interlock has no fixed circuit list, keeping the load under that ceiling is yours to manage by hand at the panel door.
Sources
- US Consumer Product Safety Commission — Portable Generator Information CenterThe 20-foot placement guidance that sets the minimum practical cord length referenced on this page.
Read next

Best Compact Interlock
Compact Interlock Kits for Small Panels
Compact interlock kits for 100 A and 125 A panels, ranked by panel brand and published breaker spacing, with the amperage confusion cleared up first.
Top pick · Eaton BRMIKBR Factory Interlock Kit 100-125A
$98.21See the BRMIKBR Factory Interlock Kit 100-125A on Amazon
Best Interlock Kit
The Best Generator Interlock Kits
Interlock kits by panel brand with the published breaker-spacing figures, and the factory kit that removes fit risk.
Top pick · Eaton BRMIKBR Factory Interlock Kit 100-125A
$98.21See the BRMIKBR Factory Interlock Kit 100-125A on Amazon
Reference
Interlock Kit Panel Compatibility
A reference table of published interlock breaker-spacing figures by panel brand and amperage, plus how to identify your panel.

Reference
Are Generator Interlock Kits Legal?
The code basis for mechanical interlocks, why acceptance varies locally, and how to find out before you buy.

Connection Comparison
Interlock Kit vs Transfer Switch
Interlock kit against transfer switch on cost, circuit access, load management, panel fit and inspection risk.

Guide
Transfer Switch Amp Rating Guide
Matching transfer switch amp rating to generator output, with the arithmetic and the whole-chain cost implications.


